Product Introduction:
This series of controllers is specially designed for starting, stopping, parameter monitoring and fault monitoring of diesel, gasoline, and gas generator sets and has parameter setting functions.
This controller uses a 3.0-inch large-screen dot matrix LCD to display relevant parameters of the generator set. The LCD screen can display multiple current fault states at the same time, and can effectively implement protective shutdown when the generator set is not working properly.
The controller has built-in display interfaces in Simplified Chinese and English, and the language interface can be customized according to customer requirements. All parameters of the controller can be adjusted through the buttons on the controller panel or adjusted and monitored using a PC through USB or RS485 interface (equipped with some models). It can be widely used in various types of generator set automation systems.
Performance and features
The DC4xD MK3 series is available in five models:
DC40D MK3: used for stand-alone automation, controlling the automatic starting and stopping of the generator set through remote start signals;
DC42D MK3: Based on D40D, it adds mains power monitoring and mains/generation automatic switching control (AMF) functions, and is suitable for stand-alone automation systems consisting of one mains power supply and one generator set.
DC40DR MK3: Adds RS485 interface on the basis of DC40D;
DC42DR MK3: Adds RS485 interface on the basis of DC42D;
DC42DR-ABF MK3: Based on DC42DR, it adds ABF backup battery pack measurement and unit control functions;
The main features are as follows
Controlled by a 32-bit imported high-performance microcontroller;
3.0-inch large-screen dot-matrix LCD display, with Chinese and English switches, and the language can be customized according to customer needs;
Made of PC material panel, it is effectively waterproof, oil-proof and UV-proof, has good operating feel and long service life;
Control and protection functions: realize automatic start/stop of the generator set, ATS switching and complete fault display and protection functions;
Various combinations of starting conditions (speed, frequency, oil pressure, charging) are available;
Collect and display a variety of engine and generator parameters;
Suitable for three-phase four-wire, three-phase three-wire, single-phase two-wire, two-phase three-wire (120V/240V) power supply 50/60HZ system;
The sensor curve can be customized through panel buttons and PC software;
Through the RS485 interface, the "three remote" functions can be realized using the MODBUS protocol;
With input and output port status display function;
The setting interface adopts a multi-level menu-type classification design, which is convenient and fast;
Built-in real-time clock, with duty plan and maintenance plan functions: through settings, the monthly or weekly duty plan of the generator set can be arranged, and the monthly or weekly maintenance plan of the generator can be arranged, so that the generator set can be used more flexibly ;
Equipped with protection and timing function, maintenance timing or date can be set;
Equipped with a black box function, it can save the relevant parameters of the unit at the moment of failure in real time, making it easy to find the cause of the unit failure;
It has 6 relay outputs, 4 of which are configurable, each with more than 20 optional functions, and 2 sets of outputs are passive contacts;
Equipped with 5 configurable switching inputs, each with more than 10 optional functions;
Equipped with 3 sensor analog inputs, 5 sensor types can be freely combined and configured, and the display unit can be configured;
Equipped with a waterproof ring as standard, the protection performance of the panel after installation reaches IP54 level;
Modular design: All connections are completed through European-style terminal blocks, making it very easy and convenient to assemble, connect, repair and replace the equipment;
Parameter display
Engine speed;
Engine oil pressure;
Engine cooling water temperature;
Engine oil temperature;
Engine block temperature;
Engine fuel level;
Engine battery voltage;
Engine charging voltage;
Mains phase voltage L-N (only available in DC42D MK3 series);
City wire voltage L-L (only available in DC42D MK3 series);
Generator three-phase voltage L-N;
Generator three-phase line voltage L-L;
Generator three-phase current A;
Generator frequency Hz;
Generator power factor COSφ;
Generator active power KW;
Generator apparent power KVA;
Generator reactive power KVar;
The generator generates Kwh of electrical energy this time;
The generator generates cumulative electrical energy Kwh;
Cumulative number of starts of the unit;
The current operating time of the unit;
The cumulative operating time of the unit;
Unit maintenance countdown;
Input and output status;
Current date/time.
Alarm protection
speeding
Underspeed
low oil pressure
high water temperature
High oil temperature
High cylinder temperature
low fuel level
low engine oil level
External instant alarm
Speed signal lost
Sensor open circuit
Overclocking
Underfrequency
Generation overvoltage
Generation undervoltage
Overcurrent
Current imbalance
Over power
Phase loss in power generation
Maintenance due
Low water level alarm
emergency pull over
Start failed
Battery overvoltage
Battery low voltage
Charger failed to charge
Shutdown failed
Specifications
project
Parameters
Operating Voltage
DC8V to 36V continuous power supply
Machine power consumption
Standby: 24V: MAX 1W
Operation: 24V: MAX 5W
AC voltage input
One phase two wires 50VAC-276VAC (ph-N)
Two-phase three-wire 50VAC-276VAC (ph-N)
Three-phase four-wire 50VAC-276VAC (ph-N)
Engine speed signal range
50-9000Hz
Maximum cumulative running time
99999.9 hours (minimum storage time 6 minutes)
fuel output
5Amp DC+VE supply voltage output
Motor output
5Amp DC+VE supply voltage output
Configurable relay 1
5Amp DC+VE supply voltage output
Configurable relay 2
5Amp passive contact, one normally open and one normally closed output
Configurable relay 3
5Amp passive contact normally open output
Configurable relay 4
5Amp passive contact normally open output
Excitation output
Maximum 1Amp DC+VE supply voltage output
Switch input
Effective when connected to the negative pole of the battery
working conditions
-25-65℃
storage conditions
-40-85℃
Protection level
IP54: When a waterproof ring is installed between the controller and the control panel.
Dimensions
189mm*134mm
Hole Size
160mm*120mm
weight
0.68Kg